Centre Pivot Irrigation with Pressure-Controlled Pumping

Darling Irrigation installed a Zimmatic centre pivot and pumping system for a mixed cropping, beef and sheep operation in Northern Tasmania, combining large-scale irrigation coverage with automatic pressure control to reduce pumping energy use.

Project overview

The project had been under discussion for several years, with land ownership arrangements affecting its progress. The proposed pivot extended across land the client did not own at the time of those discussions.

The completed installation included a 13-span Zimmatic 9500 series pivot measuring 722 metres in length, covering 120 hectares and operating at a flow rate of 110 litres per second.

The challenge

The irrigation area includes substantial changes in elevation, with land to the south rising approximately 30 metres above the pivot’s centre point. Maintaining the correct pressure at the end of the machine required the pumping system to respond as the pivot moved between higher and lower ground.

Around 60% of the pivot’s arc is level with or below the centre point, creating an opportunity to reduce pumping energy use when less pressure was required.

The solution

Darling Irrigation installed a pumping and pressure control system comprising:

  • A 13-span, 722-metre Zimmatic 9500 series centre pivot

  • A 110 kW Grundfos end-suction ISO pump

  • A variable speed drive to adjust pump speed

  • An analogue pressure telemetry system with a radio at the end of the pivot

The radio transmits pressure information directly from the end of the pivot to the pump. As the machine moves uphill, the system increases pump speed to maintain the required pressure at the end of the pivot.

As the machine moves onto lower ground, the system responds to the reduced pressure requirement by slowing the pump. This allows pumping output to adjust automatically to the changing terrain.

The result

The completed system provides irrigation coverage across 120 hectares, with pumping energy use adjusted to suit the pivot’s position.

At the highest point, the pump uses approximately 98 kW of power. When the end of the pivot is level with the centre point, demand falls to approximately 53 kW—nearly halving the power required under those conditions.

With around 60% of the pivot’s arc at or below the centre point, the pressure control system provides substantial opportunities for energy savings while maintaining the required operating pressure.